As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software.

With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.


Features and Benefits
-AOI: Module communication is integrated within Studio/RSLogix 5000 using a sample Add-On Instruction (AOI), or sample ladder logic file, reducing commissioning time.
-Autoscan: The new Autoscan feature reduces start up times and simplifies troubleshooting by scanning the PROFIBUS network and uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.)
-ComDTM: Allows remote Ethernet connectivity with Asset Management Software significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with this comprehensive, fully integrated engineering and maintenance environment.
-SD card slot: (SD card optional) is used for storing configuration files in the event of a disaster. It can also be used to update the firmware of the module without the need of a 1769 CPU.
  • Description
  • PROFIBUS DP Specifications
  • Slaves - Maximum 125
  • Input/Output - Maximum 244 Bytes per Slave
  • Input Data - Maximum 5712 Bytes
  • Acyclic Data - DPV1
  • Status data - 88 Bytes
  • Output data - Maximum 5760 Bytes
  • DPV1 services - Class 1 Read/Write, Class 1 Alarm, Class 2 Initiate/Read/Write/Data transport/Abort
  • Services - Global-Control, Slave-Diagnostic, Set-Parameter
  • Sync, Freeze Command - Supported
  • Baud rate - 9.6 kBaud,19.2 kBaud,45.45 kBaud,93.75 kBaud,187.5 kBaud,500 kBaud,1.5 MBaud,3 MBaud,6 MBaud,12 MBaud
  • Hardware Specification
  • PROFIBUS Interface - RS-485, max. 12 Mbps, potential free, according
  • EN 50170
  • Diagnostic Interface - 10/100 Ethernet, RJ45
  • Power Supply - +5 V ±5 % / 570 mA
  • Max. Distance Rating - 2 slots
  • Dimensions - Standard 1769 Single-slot module
  • Burst - EN 61000-4-4, 2 kV, 5 kHz
  • Surge - EN 61000-4-5, 2 kV common mode, 1 kV differential mode
  • ESD - EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect
  • Radiated/Conducted Immunity - EN 61000-4-3, 10 V/m, 30 ...1000 MHz, 80% AM, 1 kHz sine wave, EN 61000-4-6, 10 V, 0,15 ...30 MHz
  • Radiated/Conducted Emission - EN 55011 Class A
  • Vibration/Shock - IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1 Octave/min, IEC 600068-2-27, 15 g, 11 ms
  • Operating Temperature - 0°C to 60°C (32°F to 140°F)
  • Relative Humidity - 5 to 95% (non-condensing)
  • PROFIBUS conformance - Certified