As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS I/O data and acyclic messaging.


Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard I/O module allowing it to be configured via Studio/RSLogix™5000. The cyclic PROFIBUS I/O data can be configured in Studio/RSLogix™ 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.


Features and Benefits
-Rockwell Automation Encompass Approved
- PI Certified
-Remote diagnostics via Ethernet
- Supports DPV1 Acyclic Messaging
-Field-tested with multiple PROFIBUS Masters from multiple vendors
-AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000
-AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000
  • Description
  • PROFIBUS DP Specifications
  • PROFIBUS DP Cyclic Data - 244 Bytes IN / 244 Bytes OUT
  • Acyclic Read/Writes - 240 Bytes
  • Acyclic communication - DPV1 Class 1 Read/Write, DPV1 Class 1 Alarm, DP V1 Class 2 Read/Write/Data Transport
  • Baud rate - 9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud, Auto-detection mode is supported
  • Hardware Specification
  • PROFIBUS Interface - RS-485, max. 12 Mbps, potential free, according EN 50170
  • Diagnostic Interface - 10/100 Ethernet, RJ45
  • Power Supply - +5 V ±5 % / 570 mA
  • Max. Distance Rating - 2 slot
  • Dimensions - Standard 1769 Single-slot module
  • Burst - EN 61000-4-4, 2 kV, 5 kHz
  • Surge - EN 61000-4-5, 2 kV common mode, 1 kV differential mode
  • ESD - EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect
  • Radiated/Conducted Immunity - EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sine wave,EN 61000-4-6, 10 V, 0,15...30 MHz
  • Radiated/Conducted Emission - EN 55011 Class A
  • Vibration/Shock - IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1 Octave/min IEC 600068-2-27, 15 g, 11 ms
  • Operating Temperature - 0°C to 60°C (32°C to 140°F)
  • Relative Humidity - 5 to 95% (non-condensing)
  • PROFIBUS conformance - Certified