As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The MVI46 Modbus Master/Slave Network Interface Module allows Rockwell Automation SLC processors to interface with Modbus-compatible devices. Compatible devices include not only Modicon PLCs but also a wide assortment of third-party devices found in nearly every industry.


Features and Benefits
-The inRAx Modbus Master/Slave Communications module is designed to allow SLC processors to interface easily with Modbus protocol-compatible devices and hosts. -The MVI46-MCM module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the SLC processor is asynchronous from the actions on the Modbus network. A 5000-word register space in the module exchanges data between the processor and the Modbus network.
-Many host SCADA packages support the Modbus protocol, while devices commonly supporting the protocol include several PLCs, as well as many other third party devices in the marketplace. (For a partial list of devices that speak Modbus, please visit the ProSoft Tested section of the ProSoft Technology web site).
  • Specifications
  • Form Factor - Single Slot SLC chassis compatible
  • Backplane current load - 800 mA @ 5.1 VDC
  • Operating Temperature - 32° F to 140° F (0° C to 60° C)
  • Storage Temperature :: -40° F to 185° F (-40° C to 85° C)
  • Shock - 30 g operational, 50 g non-operational
  • Relative Humidity - 5% to 95% (without condensation)
  • Processor - Compatible with Rockwell Automation SLC 5/02 M0/M1 capable processors or newer
  • LED indicators - Module status, Backplane transfer status, Application status, Serial activity and error LED status
  • CFG Port (CFG) - RJ45 (DB-9M with supplied cable), RS-232 only, No hardware handshaking
  • Configuration Connector - RJ45 RS‑232 Connector (RJ45 to DB-9 cable shipped with unit)
  • Application Serial port (PRT1, PRT2) (Serial Modules) - Two RJ45 RS-232/422/485 Application ports