As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The MVI46 Modbus TCP/IIP Multi Client Network Interface Module allows Rockwell Automation SLC processors to interface easily with multiple Modbus TCP/IP server-compatible instruments and devices. The Multi Client module improves performance when controlling multiple servers on a Modbus TCP/IP network, by supporting up to 30 devices


Features and Benefits
-This module was created to improve the performance when servers are not needed on a Modbus TCP/IP network. The module supports up to 30 clients with up to 16 commands for each client, making it easy to enable/disable the commands from the ladder logic. The client command control word contains one bit for each command. -Support for the storage and transfer of up to 5000 registers to/from the SLC processor's controller tags
-User-definable module memory usage
-10/100 Base-T Ethernet compatible interface
- Configurable parameters for the client include:

-Minimum Command Delay
-User Defined Commands (Read/Write)

  • Specifications
  • Form Factor - Single Slot SLC chassis compatible
  • Backplane current load - 800 mA @ 5.1 VDC
  • Operating Temperature - 32° F to 140° F (0° C to 60° C)
  • Storage Temperature :: -40° F to 185° F (-40° C to 85° C)
  • Shock - 30 g operational, 50 g non-operational
  • Relative Humidity - 5% to 95% (without condensation)
  • Processor - Compatible with Rockwell Automation SLC 5/02 M0/M1 capable processors or newer
  • LED indicators - Module status, Backplane transfer status, Application status, Serial activity and error LED status
  • CFG Port (CFG) - RJ45 (DB-9M with supplied cable), RS-232 only, No hardware handshaking
  • Configuration Connector - RJ45 RS‑232 Connector (RJ45 to DB-9 cable shipped with unit)
  • Application Ports - Ethernet Port (Ethernet Modules), RJ45 Connector, Link and activity LED indicators, Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991, Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration