As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The MVI69L-MBS, Modbus Serial module for the CompactLogix™ series of controllers is designed for smaller applications where communication between a few Modbus Serial devices is required. This module has an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69L-MBS has a single serial port and can support either Master or Slave connectivity to interface with a variety of devices using the Modbus Protocol.


Features and Benefits
-Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
-Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
-Add-on Profile support, improving integration in the CompactLogix System
-Diagnostic data available in processor controller tags, enabling decisions to be made based upon node health
-Module configuration backed up in CompactLogix project (ACD file)
-Module acts as a co-processor reducing impact to PLC scan time
-Supports up to 240 words of I/O data
-Application port can be configured as either a Modbus Master or Modbus Slave
-Supports up to 30 Modbus Commands as a Modbus Master
-Supports Enron and Daniel style Floating point data implementations
-Most suitable for OEM and Machine Builder applications
  • Description
  • PROFIBUS DP Specifications
  • Configuration - ProSoft Configuration Builder
  • I/O Size - 240/240 - 16 bit integers
  • Communication parameters - Baud Rate: 110 to 115K baudStop Bits: 1 or 2Data Size: 7 or 8 bitsParity: None, Even, OddRTS Timing delays: 0 to 65535 milliseconds
  • Modbus Modes - RTU mode (binary) with CRC-16, ASCII mode with LRC error checking
  • Floating Point Data - Floating point data movement supported, including configurable support for Enron, Daniel®, and other implementations
  • Modbus Function Codes Supported ::
  • 1: Read Coil Status
  • 2: Read Input Status
  • 3: Read Holding Registers
  • 4: Read Input Registers
  • 5: Force (Write) Single Coil
  • 6: Preset (Write) Single Holding Register
  • 8: Diagnostics (Slave Only, Responds to Sub function 00)
  • 15: Force (Write) Multiple Coils
  • 16: Preset (Write) Multiple Holding Registers
  • 17: Report Slave ID (Slave Only)
  • 22: Mask Write Holding Register (Slave Only)
  • 23: Read/Write Holding Registers (Slave Only)