As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The MVI69L-MBTCP Modbus TCP/IP module is ideal for smaller applications that utilize the CompactLogix L2 controllers. The module has an Add-on Profile and an Add-on Instruction to reduce commissioning time.


The MVI69L-MBTCP has a single Ethernet port for diagnostic and application data. It supports both Client and Server connectivity to interface with a variety of devices using the Modbus TCP/IP Protocol


Features and Benefits
-Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
-Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
-Add-on Profile support, improving integration in the CompactLogix System
-Diagnostic data available in processor controller tags, enabling decisions to be made based upon node health
-Configuration backed up in CompactLogix project (ACD file)
-Module acts as a co-processor reducing impact to PLC scan time
-Supports up to 240 words of I/O data
-Supports up to 10 Client connections and 2 Server connections (1 each for Server Ports 502 and 2000)
-Supports Enron and Daniel style Floating point data implementation
  • Description
  • PROFIBUS DP Specifications
  • Configuration - ProSoft Configuration Builder
  • I/O Size - 240/240 - 16 bit integers
  • Floating Point Data - Floating point data movement supported including configurable support for Enron, Daniel®, and other implementations
  • Modbus Function Codes Supported ::
  • 1: Read Coil Status
  • 2: Read Input Status
  • 3: Read Holding Registers
  • 4: Read Input Registers
  • 5: Force (Write) Single Coil
  • 6: Preset (Write) Single Holding Register
  • 8: Diagnostics (Slave Only, Responds to Subfunction 00)
  • 15: Force( Write) Multiple Coils
  • 16: Preset (Write) Multiple Holding Registers
  • 17: Report Slave ID (Slave Only)
  • 22: Mask Write Holding Register (Slave Only)
  • 23: Read/Write Holding Registers (Slave Only)