As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The EtherNet/IP™ to PROFINET® IO Device (slave) gateway offers bi-directional data transfers between EtherNet/IP™ controllers and a PROFINET® IO controller. The EtherNet/IP™ Driver supports I/O connections for guaranteed data delivery or Message instructions to send data to/from the PACs. The gateway supports 1440 bytes of input data and 1440 bytes of output data for larger applications.


In addition, the gateway’s multiple I/O connections, allow you to set different RPIs for control data and module diagnostics, enabling you to optimize your Ethernet bandwidth.


Features and Benefits
- Embedded EDS Add-On Profile allows for simplified integration and reduced configuration time for Rockwell Automation PACs.
-No ladder programming is required when using I/O connections.
-Multiple I/O connections allow you to set different RPIs for status and control data, enabling Ethernet bandwidth optimization.
-Communication via an I/O connection provides guaranteed data delivery and enables the PAC to monitor for communication faults.
-SD card slot (SD card optional) is used for storing configuration files in the event of a disaster.
-ProSoft Discovery Service allows your PC to find the gateway and change its default IP address without being on the same subnet.
  • Specifications
  • Number of Class 3 Server Connections - 5
  • Supported PLC Types - PLC2, PLC5, SLC, CLX, CMPLX
  • Supported Message Types - PCCC and CIP
  • Number of Class 3 Client Connections - Connected - 2,Unconnected - 1
  • Number of Class 1 I/O Connections - 8
  • Max I/O connection sizeIn/Out - 496/496 bytes
  • Max RPI time - 10 ms per connection
  • CIP Services Supported - 0x4C - CIP Data Table Read, 0x4D - CIP Data Table Write
  • Command List - Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.
  • Command Sets - PLC-2/PLC-3/PLC5 Basic Command Set, PLC5 Binary Command Set, PLC5 ASCII Command Set, SLC500 Command Set