As some of you already know, we are moving our website from www.asteamtechnologies.com to www.asteamtechno.com as our new platform with some extra security features, optimized for Mobile view, A strong and visible call to action and many more.... Please update to your database i.e. Email addresses & web address as earliest as possible,

Thank you,
ATSPL team, Surat, India.

  • Formerly Asteam Technologies | Welcome to The Era of Automation

   +91 95378 40404

   contact@asteamtechnologies.com

Awesome Image

The SlotServer ControlLogix Metasys N2 by JCI Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and Johnson Controls Metasys N2 networks. The Metasys N2 SlotServer can be configured as a Metasys Slave or Master enabling exchange of information between Metasys Master devices such as NCM, N-30, NAE or NIE) or Metasys Slave devices such as UNT, VMA, DX9100, VAV or AHU.


Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module.


Features and Benefits
-FieldServer Technologies has been a leader in Metasys Gateways for many years, successfully interfacing Metasys N2 to a wide variety of building automation and process controls.
-This same interface technology is put to use with the SlotServer to provide a ControlLogix Communications Interface that can interface to a wide variety of Metasys N2 devices as a Master or a Slave device. The SlotServer for Metasys N2 also has an extensive memory base enabling it to interface to 3000 addresses.
-SlotServers are also available for other building automation control protocols and most common fire alarm control panel protocols. For information about the specific protocol, please refer to the datasheet for that specific protocol.
-Contact ProSoft Technology to learn more about the SlotServer and the specific protocols available to meet your specific needs.
  • Specifications
  • Slot width - Single
  • BackPlane Current Load - 600 mA @ 5V
  • Operating Temperature - 0o to 60 o C (32 o to 140o F)
  • Storage Temperature :: -40o to 85o C (-40o to 185o F)
  • LED Indicators - Module Status, Backplane Transfer Status, Communications status, Configuration Error, System Error, Serial Activity, Ethernet Activity, 10/100BaseT indicator
  • Connections- TP/FT-10 (LonWorks), RS-485 (2-wire) , Ethernet (10/100BaseT)
  • Dimensions - Length: 5.11” (130 mm), Depth: 2.27” (57,7 mm), Height: 3.70” (94,0 mm)
  • Service Pin - For LonWorks commissioning
  • Mounting - Local or remote rack
  • Configuration - Configuration data is contained in the configuration CSV file downloaded to the module. Sample configuration file is included. Configuration file development service available from FieldServer Technologies or approved system integrators
  • Humidity - Up to 95% RH, with no condensation